Development of 10kW three-phase grid connected inverter Razvoj 10kW trofaznog izmjenjivača spojenoga na mrežu


Isen E., BAKAN A. F.

Automatika, cilt.57, sa.2, ss.319-328, 2016 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 57 Sayı: 2
  • Basım Tarihi: 2016
  • Doi Numarası: 10.7305/automatika.60-1.1081
  • Dergi Adı: Automatika
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.319-328
  • Anahtar Kelimeler: Grid connected inverter, Inverter modeling, Space vector pulse width modulation, Total harmonic distortion
  • Kırklareli Üniversitesi Adresli: Evet

Özet

In this paper, modeling, simulation and experimental study of a 10kW three-phase grid connected inverter are presented. The mathematical model of the system is derived, and characteristic curves of the system are obtained in MATLAB with m-file for various switching frequencies, dc-link voltages and filter inductance values. The curves are used for parameter selection of three-phase grid connected inverter design. The parameters of the system are selected from these curves, and the system is simulated in Simulink. Modeling and simulation results are verified with experimental results at 10kW for steady state response, at 5kW for dynamic response and at -3.6 kVAr for reactive power. The inverter is controlled with Space Vector Pulse Width Modulation technique in d-q reference frame, and dSPACE DS1103 controller board is used in the experimental study. Grid current total harmonic distortion value and efficiency are measured 3.59% and 97.6%, respectively.