Preparation of RF sputtered AZO/Au thin film hydrogen peroxide sensitive electrode for utilization as a biosensor


KARS DURUKAN İ., ÇALIŞKAN S., ÇETE S., ÇEVRİMLİ B. S., KINACI B., ÖZEN Y., ...Daha Fazla

Journal of Materials Science: Materials in Electronics, cilt.25, sa.7, ss.3154-3159, 2014 (SCI-Expanded, Scopus)

Özet

In this study, hydrogen peroxide (H 2 O 2 ) sensitive Al doped ZO(AZO)/Au thin film electrode has been developed for the utilization as a biosensor. A preferred c-axis oriented AZO/Au thin film was deposited on quartz substrate by RF magnetron sputtering at room temperature. Structural, morphological and optical properties of the AZO film were analyzed by X-ray diffraction, atomic force microscopy and photoluminescence. The sensor performance was characterized by electrochemical analysis device. The sensibility of prepared thin film electrodes to H 2 O 2 was studied. The dependence of amperometric response current on the glucose and cholesterol concentrations was also investigated. © 2014 Springer Science+Business Media New York.